SPECIFICATIONS

For Double Stainless Steel wire braid hose (DB Grade) and Antistatic (AS, DB) Grade.

The Smoothbore Range meets or exceeds SAE 100R14 standard.

STANDARD WALL, DOUBLE BRAID (SW, DB)

Bore Size
(Nominal)
Bore Size
(Actual)
PTFE Tube
Wall
Thickness
Braid
Outside
Diameter
Minimum
Bend
Radius
Maximum
Working
Pressure
Weight per
Unit Length
*Part Number
in mm in mm in mm in mm in Bar psi kg/mtr lbs/ft
1/8 3.17 0.125 0.76 0.030 6.85 0.270 20 7/8 360 5238 .100 .067 70-100-02-02-02
3/16 4.76 0.188 0.76 0.030 8.70 0.343 30 1 1/4 330 4802 .135 .091 70-100-03-02-02
1/4 6.35 0.250 0.63 0.025 10.05 0.396 40 1 5/8 290 4220 .160 .107 70-100-04-02-02
5/16 7.94 0.313 0.63 0.025 11.55 0.455 50 2 250 3638 .190 .127 70-100-05-02-02
3/8 9.53 0.375 0.63 0.025 13.35 0.526 60 2 3/8 230 3347 .214 .143 70-100-06-02-02
1/2 12.70 0.500 0.76 0.030 16.40 0.646 90 3 5/8 180 2629 .341 .229 70-100-08-02-02
5/8 15.88 0.625 0.76 0.030 19.95 0.785 130 5 1/8 135 1964 .416 .279 70-100-10-02-02
3/4 19.05 0.750 0.76 0.030 23.10 0.910 170 6 3/4 100 1455 .503 .337 70-100-12-02-02
1 25.40 1.000 1.00 0.039 26.90 1.165 270 10 3/4 70 1019 .700 .469 70-100-16-02-02

HEAVY WALL, DOUBLE BRAID (HW, DB)

Bore Size
(Nominal)
Bore Size
(Actual)
PTFE Tube
Wall
Thickness
Braid
Outside
Diameter
Minimum
Bend
Radius
Maximum
Working
Pressure
Weight per
Unit Length
*Part Number
in mm in mm in mm in mm in Bar psi kg/mtr lbs/ft
1/8 3.17 0.125 1.00 0.039 7.05 0.278 18 3/4 350 5093 .108 .072 70-200-02-02-02
3/16 4.76 0.188 1.00 0.039 8.90 0.350 25 1 320 4656 .140 .094 70-200-03-02-02
1/4 6.35 0.250 1.00 0.039 10.75 0.423 26 1 1/8 310 4511 .183 .123 70-200-04-02-02
5/16 7.94 0.313 1.00 0.039 12.35 0.486 35 1 1/2 275 4001 .210 .141 70-200-05-02-02
3/8 9.53 0.375 1.00 0.039 14.10 0.555 50 2 240 3492 .243 .163 70-200-06-02-02
13/32 10.32 0.406 1.00 0.039 15.05 0.593 60 2 3/8 230 3347 .258 .173 70-500-13-02-02
1/2 12.70 0.500 1.00 0.039 16.90 0.665 75 3 200 2910 .374 .251 70-200-08-02-02
5/8 15.88 0.625 1.30 0.051 20.75 0.817 100 4 155 2255 .452 .303 70-200-10-02-02
3/4 19.05 0.750 1.30 0.051 23.80 0.937 135 5 3/8 110 1601 .532 .356 70-200-12-02-02
1 25.40 1.000 1.50 0.059 30.70 1.209 250 9 7/8 84 1222 .730 .489 70-200-16-02-02
1 1/4 31.75 1.250 1.50 0.059 36.90 1.453 400 15 3/4 75 1091 .905 .637 70-200-20-02-02
1 1/2 38.10 1.500 1.50 0.059 43.75 1.722 800 31 1/2 65 946 1.170 .784 70-200-24-02-02
2 50.80 2.000 1.50 0.059 56.40 2.221 1200 47 1/4 40 582 1.610 1.079 70-200-32-02-02

MEDIUM WALL, DOUBLE BRAID (MW, DB) also referred to as HYPERLINE SB, DB)

Bore Size
(Nominal)
BB = Big
Bore
Bore Size
(Actual)
Dash Size
Reference
(if any)
PTFE Tube
Wall
Thickness
Braid
Outside
Diameter
Minimum
Bend
Radius
Maximum
Working
Pressure
Weight per
Unit Length
*Part Number
in mm in mm in mm in mm in Bar psi kg/mtr lbs/ft
1/16 BB 2.0 0.079 -2 1.00 0.040 6.00 0.236 11 1/2 540 7800 .075 .050 70-300-02-02-02
1/8 BB 3.5 0.138 -3 1.00 0.040 7.45 0.293 18 3/4 350 5000 .111 .074 70-300-03-02-02
3/16 BB 5.0 0.200 -4 0.76 0.030 8.80 0.347 35 1 3/8 340 4900 .128 .086 70-400-03-02-02
1/4 BB 6.7 0.264 -5 0.76 0.030 11.00 0.433 50 2 320 4600 .170 .114 70-400-04-02-02
5/16 BB 8.5 0.335 -6 0.76 0.030 11.82 0.466 60 2 3/8 270 3900 .215 .144 70-400-05-02-02
3/8 BB 10.0 0.394 0.76 0.030 14.20 0.560 80 3 230 3300 .260 .174 70-400-06-02-02
1/2 BB 13.6 0.536 -10 0.76 0.030 17.35 0.684 110 4 3/8 180 2600 .350 .234 70-400-08-02-02
5/8 BB 16.6 0.654 -12 0.84 0.033 20.80 0.820 140 5 1/2 130 1900 .450 .300 70-400-10-02-02
3/4 BB 19.8 0.780 1.00 0.040 24.00 0.946 160 6 1/2 120 1700 .520 .350 70-400-12-02-02
1 BB 26.4 1.040 1.00 0.040 31.70 1.249 210 8 1/4 100 1400 .830 .550 70-400-16-02-02

* For Anti-Static Grade, add 10 to the 3-digit Part Number e.g. 70-100 becomes 70-110.
For High Pressure Gas Grade, add 20, e.g. 70-100 becomes 70-120.

Note: A few of the sizes of hose and fittings listed above are available as ex-stock items and are priced accordingly. However, most of the items are not stocked, and will therefore incur a minimum order charge or a set-up charge for small quantities.

Temperature & Pressure

- Temperature affects the Maximum Working Pressure (MWP) as listed above, so for temperatures above 130°C reduce the MWP by 0.75% for each 1°C above 130°C. Example: at 180°C, reduce the MWP by (180 - 130) x 0.75 = 37.5%.

- Pressure Ratings above 100 Bar (1500 psi) only apply for the transfer of non-penetrating fluids. If gases or penetrating fluids are used at higher pressures, HPG grade hose is required.

- Maximum Working Pressures (MWP) listed are calculated on the basis of a 3:1 safety factor relative to the burst pressure, so Burst Pressure = 3 x MWP. If MWP is required based on a 4:1 safety factor, multiply the listed value by 0.75.

 
< Prev   Next >

Newsletter

Please subscribe to our newsletter for details of new products and applications.

E-mail Address:
Subscribe:
UnSubscribe:

Language

 French German Spanish
 Chinese Japanese English

Site Search

Hyperline

Hyperline

The Hyperline range of hose products is designed for assembly with standard, off the shelf hydraulic fittings, using ferrules supplied by Aflex Hose. 

Read more...

 

Who's Online

We have 15 guests online

 

Company Information

Aflex Hose Limited is a company registered in England and Wales.

Registered No: