Smoothbore Hose Special Usage Conditions Print E-mail

PTFE HOSE - USE WITH ALKALI METALS, HALOGENS AND HALOGEN CONTAINING CHEMICALS

PTFE hose liners react chemically with Fluorine, Chlorine Trifluoride and molten Alkali Metals.

When PTFE lined hose is used to carry Chlorine or Bromine, either as gasses or fluids, they will diffuse into and through the PTFE liner wall thickness. Trace quantities will then combine with atmospheric moisture to corrode any braid/rubber outer coverings.

Heavily halogenated chemicals, like Hydrogen Fluoride, Hydrogen Chloride, Phosgene (Carbonyl Chloride) Carbon Tetrachloride and other organic chemicals with a high halogen content can also be absorbed and transmitted through the PTFE liner tube.

OTHER 'PENETRATING' FLUIDS AND GASES

Sulphur Trioxide, Methyl Methacrylate, Caprolactam and Glacial Acetic Acid are some other chemicals which can be absorbed and transmitted through the PTFE liner tube wall.

Generally, however, as a hydrophobic (non-wetting) material, PTFE is very resistant to the absorption of chemicals. In some cases, PTFE has superior resistance to diffusion, for example to the diffusion of automotive fuels, in comparison with all other plastics and rubbers.

GAS/FLUID CYCLING

There are some applications where the fluid passing through the hose turns into a gas, then back into a fluid, then into a gas etc, in a cyclic sequence.

This is normally associated with changes in temperature and/or pressure. For complex reasons these conditions are extremely damaging to the hose liner, whatever material it is made from.

For example, hoses are sometimes used to pass steam, water, steam etc into rubber moulding presses, in order to heat the mould, then rapidly cool it before reheating in the next cycle. Hoses of all types fail rapidly in such an application and PTFE lined hoses are no exception.

Please contact Aflex Hose for further information if these conditions apply.

CONNECTING ASSEMBLIES FOR USE IN APPLICATIONS

The lengths of hose assemblies and their configuration in use when connected into the application must always be in accordance with the Hose Configuration information at the end of this product literature.

When being connected for use in applications, the end fittings on hose assemblies must be connected to correct mating parts in the correct way, using the correct tools, spanners, clamps, nuts and bolts etc. The connections must be sufficiently tightened to ensure that the joint is leak free but not be over tightened as this can damage the sealing surfaces.

In applications involving the transfer through the hose of expensive or dangerous fluids or gases, the hoses and connections must be pressure tested in situ before being put in to service. This should be done with some harmless media to 1 1/2 times the maximum working pressure of the hose assembly, as stated in the product literature.

If in doubt please contact Aflex Hose for advice.

SPECIAL APPLICATIONS

Aflex Hose PTFE lined hose products are not rated as suitable for use in the following, special applications:

All Radioactive Applications involving high energy radiation, including Gamma radiation (degrades PTFE).

All Medical Implantation Applications.

All Aerospace Applications.

 
< Prev   Next >

Newsletter

Please subscribe to our newsletter for details of new products and applications.

E-mail Address:
Subscribe:
UnSubscribe:

Language

 French German Spanish
 Chinese Japanese English

Site Search

Relink

Relink reusable end fittings

A range of reusable fittings and ferrules that allow you, the Customer, the opportunity to assemble our Pharmaline and Pharmalex range on site or in your workshops or vans. Based around a manual or hydraulic press and using no screw threads, it brings hygienic self-assembly hoses combined with the Aflex quality to you.

Read more...

 

Who's Online

We have 23 guests online

 

Company Information

Aflex Hose Limited is a company registered in England and Wales.

Registered No:

1088141

Registered Address:

Spring Bank Industrial Estate,

Watson Mill Lane,

Sowerby Bridge,

Halifax.

West Yorkshire.

HX6 3BW

Telephone:

+44-1422-317200

Fax:

+44-1422-836000

Email:

postmaster@aflex-hose.co.uk

VAT:

GB 184 3235 64

DUNS:

UK 213 251 010

USA 104 191 130

Syndicate