SS - STAINLESS STEEL BRAID
PURPOSE
Stainless Steel braided hose can be used in applications
involving high temperatures and working pressures. High
tensile AISI 304L stainless steel wire is used, to give
maximum pressure resistance and external protection to
the hose.
PB - POLYPROPYLENE BRAID
PURPOSE
Polypropylene braided hose is often preferred to SS in
applications involving frequent handling and movement of
the hose. PB braid is lighter in weight, and any broken
strands will not cut the operator’s hands. In addition, PB
braid is not prone to 'chloride stress corrosion', and has
generally good chemical resistance.
To ensure *Electrical Continuity* between end fittings, 2
strands of Monel wire earthing strips are criss-crossed on
to the liner, underneath the Polypropylene Braid. These are
folded back underneath the ferrule at both end fittings, to
make an electrical contact.
NOTE: Prolonged exposure to sunlight eventually results in
UV degradation of PB braid.
RC - RUBBER COVER
PURPOSE
RC Grade hose is the general purpose product, used in a
wide variety of applications. A Black, Antistatic EPDM
rubber to extruded over the SS braided product, to protect
the SS braid with a tough, abrasion resistant rubber cover.
The rubber cover hose has a smooth finish, to make it easy
to wipe clean.
A yellow 'CORROLINE' stripe is printed on to the cover.
Other texts and coloured stripes are available to special
order.
RC Grade hose assemblies are 'FIRE RESISTANT' to
BS5173 Section 103.13 Parts 6.2 and 6.3. if Hose
Assemblies are further required to be 'FIRE PROOF' this
can be achieved by adding double rubber cover end
protection to give extra fire protection
at the ends of the assembly.
*SPECIAL NOTE*
*ELECTRICAL CONTINUITY*
*Electrical continuity requires that the hose assembly
supplied is electrically continuous, or conductive, between
metal end fittings at each end of the hose. This can apply
whether the hose is GP or AS grade.
The requirements for electrical continuity are specified in
the German Document BRG132, and the Specification EN
ISO 12115, tested to EN ISO 8031 Clause 3.7, which
requires that for hose assemblies with a resistance
between fittings of ≤102 ohms, a letter 'M' can be
applied, or ≤106 ohms, a letter 'Ω' can be applied.
Corroline Hose Assemblies are all electrically continuous
with a resistance of <20 ohms, and therefore meet the
requirements of both 'M' and 'Ω', but are not stamped
unless requested.
|