Flange Specification
- ANSI B16.5 (also ASME B16.5) Class 150# and 300#
- *DIN PN10/16/40 up to 2” size, PN10/16 from 21/2” up to 6” size
- JIS 10K
- Other Pressure Ratings and Flange Specifications are also available
*The dimensions for flanges to the different pressure ratings are identified, so they are inter-changeable.
Maximum Pressure Ratings for Flange Fittings
- ANSI 150# = 16 Bar (230 psi), ANSI 300# = 32 Bar (460 psi)
- DIN PN10 = 10 Bar (145 psi)
- DIN PN16 = 16 Bar (230 psi), DIN PN40 = 40 Bar (580psi)
End Fitting Materials
- Flanges in Grade 304 SS
- Flange Retainers in Grade 316L SS
- Ferrules, most in Grade 304 SS, some sizes in Grade 316L SS
Alternative options for Flange component only:
- Zinc Plated Carbon Steel
- Blue Epoxy Coated Carbon Steel.
90° Elbow Flange Fittings
90° Elbow Integral PTFE lined Flange Fittings are available for 1”, 1 1/2” & 2”.
Integral PTFE Lined Swivel Flange Fittings

Nominal Size
- Flange & Hose |
*Fitting Length
A |
Flared Diameter D |
Recommended Bolt
Tightening Torques |
Weight/
Fitting |
| in |
mm |
in |
mm |
ASA150 mm |
PN10/16 mm |
ft.lbs |
Nm |
kg |
| 1/2 |
15 |
1.65 |
42 |
32.0 |
32.0 |
8 |
10.79 |
0.54 |
| 3/4 |
20 |
2.28 |
58 |
43.0 |
50.0 |
8 |
10.79 |
0.88 |
| 1 |
25 |
2.28 |
58 |
50.8 |
63.5 |
10 |
13.73 |
0.96 |
| 1 1/4 |
32 |
3.48 |
63 |
63.0 |
78.0 |
12 |
16.67 |
1.36 |
| 1 1/2 |
40 |
2.40 |
61 |
73.0 |
88.0 |
15 |
20.59 |
1.75 |
| 2 |
50 |
2.52 |
64 |
92.0 |
102.0 |
25 |
34.32 |
2.70 |
| 2 1/2 |
65 |
3.11 |
79 |
105.0 |
122.0 |
30 |
41.18 |
4.00 |
| 3 |
80 |
3.11 |
79 |
127.0 |
127.0 |
40 |
53.94 |
5.00 |
| 4 |
100 |
5.20 |
132 |
158.0 |
158.0 |
40 |
53.94 |
7.00 |
| 6 |
150 |
3.66 |
93 |
213.0 |
213.0 |
50 |
67.67 |
13.00 |
*Fitting Lengths listed are for Corroflon braided only hose grades (SS,PB,HB,KYB). Approximately 33% longer lengths apply to the rubber covered hose grades (RC,SI,FP).
*"STEP-UP" PTFE LINED FLANGE FITTING DESIGN FOR CORROFLON HOSE
Adapting for Different Flange Sizes
To fit larger than nominal flange sizes
It may be necessary to fit a larger than nominal flange size to the hose - for example, 3” flange fitted to one end of a 2” hose - in which case it may also be necessary to increase the diameter of the sealing face to the correct size for the larger flange. This can be achieved by means of a flange adaptor as shown.
To fit smaller than nominal flange sizes
Within limits, it is also possible to make up an assembly with a flange one size smaller than the nominal size. The smaller flange is bored out and fitted to the larger hose and, if necessary, the flared diameter is reduced to suit.
Consult the supplier if a different flange size is required.
|