Electrically Traced Heated Assemblies - ETH Grade Print E-mail

Purpose

For use in applications where the temperature of the process fluid entering the hose assembly must be regulated as it passes through the hose. This is usually required to prevent solidification or an increase in the fluid viscosity. In some applications, an additional ‘heating up’ or ‘melting’ facility is also required. Electrical heating is often preferred to steam heating because it is more convenient, more controllable and usually more readily available. ‘Zone 1 Hazardous Area’ requirements can be met.

Description

The heating element comprises either a resistance element or a self-regulating element spirally wrapped around the hose assembly. Self regulating elements may require a sensor and controller if a specific maintain temperature is required. Please consult Aflex Hose for clarification. Resistance element heated hoses usually also require a temperature sensor to be built in to the construction and must be used in conjunction with a temperature controller. The power leads and (if applicable) temperature sensor leads emerge from the hose assembly at one end, through glands and conduits. The thermal insulation is foam rubber, closed-cell fire resistant silicone foam rubber for temperatures above 80°C. The outer cover may be a Polypropylene Braid or SS wire braid with a rubber cover if necessary.

Design

Each hose is custom designed and built to suit the requirements of the particular application. Application details must be supplied by filling in an “ETH Hose Questionnaire”, available from Aflex Hose. Generally, for Hazardous Areas, the Self Regulating type of heating element is employed, with or without a temperature sensor and control, and flameproof glands and conduit are also required. The watts per metre of the heating element, the pitch of the spiral on the hose, and the thickness of the thermal insulation are all calculated in accordance with established formulae to give the required maintained temperature for the process fluid passing through.

Specifications

As for Corroflon GP, SS except that the minimum bend radius is tripled and the outside diameter and weight are significantly increased in line with the particular design. Maximum ETH Hose Assembly Lengths are as given for Corroflon GP, SS.

Limitations

1” PTFE lined PN10 flange spigots on heated hoses can only have a maximum flare diameter of 50mm, not 63mm.

Minimum ETH Hose Assembly Length, when collars are used 750mm.

 
< Prev   Next >

Newsletter

Please subscribe to our newsletter for details of new products and applications.

E-mail Address:
Subscribe:
UnSubscribe:

Language

 French German Spanish
 Chinese Japanese English

Site Search

Corroflon

Corroflon

Corroflon was launched in 1978 and, since then has been continually updated and improved. Now it is the industry-standard convoluted flexible PTFE hose for major chemical, pharmaceutical and food companies worldwide.

Read more...

 

Who's Online

We have 6 guests online

 

Company Information

Aflex Hose Limited is a company registered in England and Wales.

Registered No:

1088141

Registered Address:

Spring Bank Industrial Estate,

Watson Mill Lane,

Sowerby Bridge,

Halifax.

West Yorkshire.

HX6 3BW

Telephone:

+44-1422-317200

Fax:

+44-1422-836000

Email:

postmaster@aflex-hose.co.uk

VAT:

GB 184 3235 64

 

Syndicate