SS - Stainless Steel Braid

Purpose - Corroflon GP,SS is the general purpose grade
of hose and has been carefully designed to satisfy the widest range of
application requirements.
Design - The hose liner is manufactured from hose
quality grade PTFE conforming to FDA requirements 21 CFR 177.1550 and USP Class
VI, extruded in to tube and helically convoluted. It also includes a heavy
gauge Grade 304 stainless steel reinforcing wire helically wound into the
external root of the convolutions to strengthen the convoluted shape. The
braid is high tensile grade 304 stainless steel wire braid to give maximum
protection to the hose against internal pressure and external abrasion.
PB - Polypropylene Braid

Purpose - Polypropylene braided hose is often
preferred to SS Braid in application involving frequent handling and movement of
the hose, and where temperatures are within the range -30°C to +100°C. PB
braid is lighter in weight and any broken strands will not cut the operator's
hands. In addition, PB braid is not prone to chloride stress
corrosion.
NB Electrical Continuity is maintained between end
fittings by welding the helix wire to the spigot or ferrule at each end.
Specification As for GP,SS except that the operating
temperature range (internal) is reduced to -30°C to +100°C, and the weight per
meter is reduced by about 20%.
NOTE: Prolonged exposure to sunlight eventually results in UV degradation of PB braid.
HB - Hastelloy Braid (C276 grade)

Purpose - Hastelloy Wire Braid is used instead of SS
where severe chemical corrosion conditions exist around the outside of the
hose. One way in which this can happen is when Chlorine or Fluorine are
being transferred. Diffusion of trace quantities of such gases through the
PTFE liner can lead to atmospherically wetted fluorine or chlorine attacking the
braid material, in which case the Hastelloy Braid would be resistant.
Specifications - Same as for SS except that Burst
Pressure and MWP are 50%.
KYB - Kynar Braid (Polyvinylidene Fluoride
Monofilament)

Purpose - Kynar Braid is primarily used where severe
chemical corrosion conditions exist around the outsides of the hose. This
can happen when Chloride or Fluorine are being transferred. Diffusion of
these gases through the PTFE liner can lead to atmospherically wetted chlorine
attacking the braid material, in which case the Kynar Braid would be
resistant. For such applications it is recommended that Aflex Hose should
always be given full application details to ensure an appropriate
recommendation. Other, special braid alternatives for such applications
include, Monel and Hastelloy C276 wire.
Specification - As for GP,SS except that the maximum
working pressure is reduced by 50%, the maximum operating temperature (internal)
is 120°C and the weight per metre is reduced by 30%.
TO - Tube Only (no braid)

Purpose TO grade hose is a lightweight hose, used in
applications where working pressures are low and where there is no need for the
physical protection offered by an external braid.
|