Purpose - For use in applications where the temperature of the process fluid must be maintained as it passes through the hose. This is usually required to prevent solidification or an increase in fluid viscosity. Steam heating is preferred to electrical heating in some applications for reasons of availability or safety, but is less controllable.
Description - The heating element comprises a small diameter PTFE heating hose, 6mm or 9.5mm bore size, with a single stainless steel wire braid. This is spirally wrapped around the hose, with inlet and outlet ports attached, either both at one end or at opposite ends of the hose assembly. In the case of hose assemblies longer than 3 metres, it is usual to have several heating hoses with inlet ports at opposite ends and along the hose. This reduces the effect of temperature loss over the length of the Hose Assembly. The thermal insulation is usually closed-cell silicone foam rubber. The outer cover is a stainless steel wire braid with a rubber cover if necessary.
Design - Each hose is custom designed and built to suit the requirements of the particular application. The following information is therefore required.
- Fluid in Hose Assembly
- Maintained Temperature of Fluid in Hose
- Temperature of Steam or Fluid in the Heating Hose
- Minimum/Maximum Ambient Temperature
- Pressure/Vacuum Applied to Fluid
- External Conditions of Abrasion etc.

Specification - All as per Bioflex GP,SS except that the minimum bend radius is tripled and the outside diameter and weight are significantly increased in line with the particular design.
Limitations - 1" PTFE lined PN10 flange spigots on heated hoses can only have a maximum flare diameter of 50mm, not 63mm. If the hose is "hanging" straight or at 90º, under its own weight, special construction is required, so advise Aflex Hose accordingly.
Minimum CH Hose Assembly length 750mm.
|